Monitor > Assign SNMP

SNMP Monitoring is managed by a specific Machine ID(SNMP Relay) that will perform SNMP Commands on the Devices.  Machines with an SNMP Community applied will show up in the Machine ID list.  To add a machine as a SNMP Relay go to the SNMP Community function.  By clicking the machine (SNMP Relay) a list of SNMP Devices will be displayed, if no Devices are displayed go the the LAN Watch function to scan for new devices.

SNMP Sets can be applied to a any device with the following parameters.  

If you check any of these boxes the action will be performed on the monitor set for that device when an alarm is created. You can select monitor sets from the Select Monitor Set list to apply to machine IDs.  To add/edit monitor sets go to the SNMP Sets function.  You may assign more than one monitor set to the same device.

Apply

Applies the selected monitor set to the checked device(s).

Clear

Clears the selected monitor set from the checked devices(s)

Clear All

Clears all the monitor sets from the selected device(s).

Create Alarm

The Create Alarm check box is always checked.  This will create an alarm for any monitor set object that goes into alarm threshold.

Create Ticket

When an alarm is generated you can set up the system to automatically generate a new ticket at the same time the alarm is created. This new ticket will be associated to the new alarm.

Run Script after alarm

When an alarm is generated you can set up the system to automatically run a script at the same time the alarm is created. You can run the script on the machine that generated the alarm or any other machine you wish.

Email Recipients

Email address where the alarm notification is sent. You can specify a different email address for each device, even if it is for the same alarm. The "From:" email address is specified in the Server Info function of the System feature tab. The alarm notification may be sent to more than one email address by putting a comma before each additional address.

Add to current list

Select this radio button to add the email address to the current list of recipients for that alarm. If the name is already on the list for a selected device, then any changes to alarm settings are applied but the address list remains the same.

Replace list

Set the recipient email list for this alarm to the list entered. This over-writes any existing email list.

Remove

Remove an email address from the recipient list for all selected machines without modifying any alarm parameters. Use this button to quickly remove an email address for alarms without having to worry about setting up alarms parameters.

Format Email

Change the default message sent with each email alarm by clicking this button.

Select Monitor Set

Select list containing monitor sets that can be applied to device(s).  To add/edit monitor sets go to the Define SNMP Set function.

Add Monitor Set

When a monitor set is applied to device(s), the selected monitor set will be added to the list of current monitor sets on that Machine.

Replace Monitor Set(s)

When a monitor set is applied to device(s), the selected monitor set will be added to the device replacing all monitor sets deployed to that device.

Name

List of SNMP devices generated for the specific Mahcine ID by the LAN Watch function.

Device IP

IP Address of device.

MAC Address

MAC Address of device.

SNMP Info

SNMP Device information.

SNMP Sets

List of monitor sets that have been assigned to the device.

ATSE

Assign monitoring parameters to execute when an alarm is created:

Email Address

List of Email Addresses to notify when an alarm is created for the specific monitor set.