The Log file monitor can read a text file and check for appended lines containing one of the specified strings. The monitor generates an alarm if the specified search criteria are met. The monitor uses SMB for connecting to an asset. This means that the only credentials configurable are Windows accounts. You will need to set a Windows account even if the target operating system is non-Windows using Samba.
Note: Only monitor specific settings are documented here. See Standard monitor settings.
Monitor specific properties
\\myhost\C$\test.txt
.Path field formatting flags
The following formatting variables can be included when specifying a path.
%[system.time_hour]
- Hour in 24-hour format (00 -23)%[system.time_hour2]
- Hour in 12-hour format (01 -12)%[system.time_minute]
- Minute as decimal number (00 -59)%[system.time_second]
- Second as decimal number (00 – 59)%[system.date_year]
- Year with century, as decimal number%[system.date_year2]
- Year without century, as decimal number%[system.date_month]
- Month as decimal number (01 – 12)%[system.date_day_of_month]
- Day of month as decimal number (01 – 31)%[system.date_day_of_year]
- Day of year as decimal number (001 – 366)%[system.date_weekday]
- Weekday as decimal number (0 – 6; Sunday is 0)