Next Topic

Previous Topic

Book Contents

SMS settings

Network Monitor can send SMS through a modem connected to the Network Monitor host machine. The modem can either be a GSM phone or a modem capable of sending SMS via a fixed line service provider. The SMS settings tab configures the logical settings required to enable the connection.

Configuring the modem

  1. Select the serial port the GSM modem is connected to.
  2. Select the baud rate. Defaults to 9600.
  3. (Optional) Enter the PIN code to unlock the SIM card.
  4. Click the Save button to store the new settings.

User phone number

An SMS phone number must be specified for each user receiving SMS notifications from Network Monitor using either of the following:

Word 80% / HTML 80% > Users and user groups > Create a new user > Basic properties tab > SMS number field

Word 80% / HTML 80% > My settings > Edit my settings > Basic properties tab > SMS number field

Tested SMS devices

Along with this list, almost all modern GSM phones and modems work. The device must support Text mode SMS and be able to connect to a COM port. A device may also connect to an USB port but the device driver must be able to emulate a standard serial port so it can be discovered by Network Monitor.

SMS modem installation checklist

The device should be connected to a serial port, or USB port with serial emulation, on the Network Monitor host machine.

  1. Connect the phone cable to the Network Monitor host machine.
  2. Install the modem driver for your phone (if required).
  3. With a terminal program connect to the phone.
  4. Try to send a SMS by typing the following.
  5. The SMS should now be sent. Remember to replace <PHONENUMBER> with the number of the receiving phone and keep the quote signs (e.g. "0068455"). On the last line you should press the CTRL-Z key combination.
  6. The phone should answer with CMGS followed by a number indicating the ID of the sent SMS.
  7. The phone is now ready for use by Network Monitor.

CMS Error codes

8

Operator determined barring

10

Call barred

21

Short message transfer rejected

27

Destination out of service

28

Unidentified subscriber

29

Facility rejected

30

Unknown subscriber

38

Network out of order

41

Temporary failure

42

Congestion

47

Resources unavailable, unspecified

50

Requested facility not subscribed

69

Requested facility not implemented

81

Invalid short message transfer reference value

95

Invalid message, unspecified

96

Invalid mandatory information

97

Message type non-existent or not implemented

98

Message not compatible with short message protocol state

99

Information element non-existent or not implemented

111

Protocol error, unspecified

127

Interworking, unspecified

128

Telematic interworking not supported

129

Short message Type 0 not supported

130

Cannot replace short message

143

Unspecified TP-PID error

144

Data coding scheme (alphabet) not supported

145

Message class not supported

159

Unspecified TP-DCS error

160

Command cannot be actioned

161

Command unsupported

175

Unspecified TP-Command error

176

TPDU not supported

192

SC busy

193

No SC subscription

194

SC system failure

195

Invalid SME address

196

Destination SME barred

197

SM Rejected-Duplicate SM

198

TP-VPF not supported

199

TP-VP not supported

208

D0 SIM SMS storage full

209

No SMS storage capability in SIM

210

Error in MS

211

Memory Capacity Exceeded

212

SIM Application Toolkit Busy

213

SIM data download error

255

Unspecified error cause

300

ME failure

301

SMS service of ME reserved

302

Operation not allowed

303

Operation not supported

304

Invalid PDU mode parameter

305

Invalid text mode parameter

310

SIM not inserted

311

SIM PIN required

312

PH-SIM PIN required

313

SIM failure

314

SIM busy

315

SIM wrong

316

SIM PUK required

317

SIM PIN2 required

318

SIM PUK2 required

320

Memory failure

321

Invalid memory index

322

Memory full

330

SMSC address unknown

331

No network service

332

Network timeout

340

NO +CNMA ACK EXPECTED

500

Unknown error

512

User abort