The Alarm Summary page displays alarms for all machine IDs that match the current machine ID / group ID filter. You can include additional filtering for listed alarms using fields in the Alarm Filters panel. You can also close alarms or re-open them and add notes to alarms.
Filtering Alarms
Select or enter values in one or more of the following Alarm Filter fields. The filtering takes effect as soon as you select or enter a value.
Counter
, Process
, Service
, SNMP
, Alert
, System Check
, Security
or Log Monitoring
.Open
or Closed
. You can only select the Open
status for an alarm listed in a dashlet Alarm Summary Window.Alarm
or Trending
.*memory*
Closing Alarms
You can close alarm log records in one of two ways:
Open
link in the State column of the Alarm Summary window.Or:
Closed
.Deleting Alarms
Adding Notes
Select Page
When more rows of data are selected than can be displayed on a single page, click the and buttons to display the previous and next page. The drop-down list alphabetically lists the first record of each page of data.
Select All/Unselect All
Click the Select All link to check all rows on the page. Click the Unselect All link to uncheck all rows on the page.
Alarm ID
Lists a system-generated and unique ID for each alarm. The expand icon can be clicked to display specific alarm information.
Check-in status
These icons indicate the agent check-in status of each managed machine. Hovering the cursor over a check-in icon displays the agent Quick View window.
Online but waiting for first audit to complete
Agent online
Agent online and user currently logged on.
Agent online and user currently logged on, but user not active for 10 minutes
Agent is currently offline
Agent has never checked in
Agent is online but remote control has been disabled
The agent has been suspended
An agent icon adorned with a red clock badge is a temporary agent.
Machine.Group ID
The list of Machine.Group IDs displayed is based on the Machine ID / Group ID filter and the machine groups the user is authorized to see using System > User Security > Scopes. Each dashlet displays all machine groups and machine IDs matching the dashlet's unique machine ID/group ID filter.
Alarm Date
The date and time the alarm was created.
Type
The type of monitor object: Counter
, Process
, Service
, SNMP
, Alert
, System Check,
Security
and Log Monitoring
.
Ticket
If a ticket has been generated for an alarm a Ticket ID link displays. Clicking this link displays the ticket in the Ticketing > View Ticket page. If no ticket has been generated for an alarm a New Ticket... link displays. Click this link to create a ticket for this alarm.
Name
The name of the monitoring object.